Journal of Clinical Virology
Volume 50, Issue 1 , Pages 42-45, January 2011

Evaluation of commercial ResPlex II v2.0, MultiCode®-PLx, and xTAG® respiratory viral panels for the diagnosis of respiratory viral infections in adults

Clinical Microbiology, Department of Pathology, The Ohio State University Medical Center, 1492 E Broad Street, Columbus, OH 43205, United States

Received 19 May 2010; received in revised form 28 September 2010; accepted 29 September 2010. published online 03 November 2010.

Abstract 

Background

Commercial multiplex PCR panels for respiratory viruses (PRV) have been recently developed. ResPlex II Panel v2.0 (Qiagen), MultiCode®-PLx (EraGen Biosciences), and xTAG® (Luminex) PRV's were studied. All assays detect influenza A and B, adenovirus, parainfluenza 1–3, respiratory syncytial virus A and B, human metapneumovirus and human rhinovirus. The ResPlex II additionally detects coronavirus (229E, OC43, NL63, HKU1), coxsackie/echo virus, bocavirus and differentiates adenoviruses (B, E). The MultiCode-PLX assay detects 229E, OC43, and NL63, differentiates parainfluenza 4a, 4b and adenoviruses (B, C, E). The xTAG additionally subtypes influenza A as seasonal H1 and H3.

Study design

202 specimens collected from adult patients with signs of respiratory infection from November, 2008 to May, 2009 were used for evaluating the performance of the three commercial PRV assays. Viral culture and xTAG were used as the standards to assess sensitivity and specificity.

Results

The PRV assays detected more viruses than culture. When compared to culture, the xTAG PRV showed a sensitivity and specificity of 100% and 91%, compared to MultiCode-PLx with 89% and 87%, and ResPlex II with 89% and 94%, respectively. Co-infection was detected in a small subset of patient specimens. Each panel showed differences in sensitivities for individual viruses.

Conclusions

While the ResPlex II and MultiCode-PLx offer a broader virus detection range and greater ease of use, the xTAG PRV showed increased sensitivity to common viral targets represented in the assays, and also had the ability to differentiate human from non-human influenza A H1.

Keywords: Respiratory virus panel, RVP, Respiratory viruses, xTAG, ResPlex II, MutiCode®-PLx

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1386-6532(10)00406-3

doi:10.1016/j.jcv.2010.09.022

Journal of Clinical Virology
Volume 50, Issue 1 , Pages 42-45, January 2011